Seiko TM-L60 Specifikace Strana 69

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 98
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 68
1-62 Command Descriptions Rev. A
GS <
[Name] Initialize printer mechanism
[Format] ASCII GS <
Hex 1D 3C
Decimal 29 60
GS < feeds label paper to the printing start position. This command is only effective when thermal
label is selected with the paper selection DIP switch, and does not initialize the values set by other
commands.
GS A m n
[Name] Adjust print starting position
[Format] ASCII GS A mn
Hex 1D 41 mn
Decimal 29 65 mn
[Range] 0 m 255 (Only the least significant bit of m is enabled.)
0 n 255
GS A m n adjusts the label print starting position in a selected direction, and by a specified amount
from the default position. This command is effective only when Thermal Label is selected with the
paper selection DIP switch. This command will be ignored unless it is received just after feeding a
label to the print starting position, using the FF, GS FF, or GS < commands, or by pressing the PAPER
FEED button, or at the time of power-on. The default setting is m=0, n=0. When executing the
commands, the paper is fed to adjust the print starting position of the current label, as follows.
m specifies the adjusting direction. When the LSB of m = 0, the label position is adjusted in the normal
direction. When the LSB of m = 1, the label position is adjusted in the reverse direction.
n specifies the adjustment amount. The adjustment amount formula is [n × (vertical motion unit)]
inches. The vertical motion units use the vertical value set by the GS P. The default setting of the
vertical motion unit is 1/360 inch.
Program Example
PRINT #1, CHR$(&H1D);"<";
Program Example
PRINT #1, CHR$(&H1D);"A";CHR$(0);CHR$(18);