Å
Print and eject label
210 PRINT #l, “ABCDEF”; CHR$( 10);
220 PRINT #l, CHR$(29); CHR$( 12);
210 prints data, then 220 ejects label. After ejection, an ERROR LED is lit and
waits until the paper feed switch is pressed. When the paper feed switch is
pressed after ejecting label, paper feeding is performed to set the next label
at the starting position for printing.
Æ
Close RS-232C
230
CLOSE #l
RS-232C must be closed using this command.
n n
Sample Program onto thermal label paper
100 OPEN “COMl: N81NN” AS #l
110 PRINT #l, CHR$(29); "<”;
120 PRINT #l, “ABCDEF”; CHR$( 10);
130 PRINT #l, CHR§( 12);
140 PRINT #l, CHR$(29); “CO”; CHR$(3); CHR$(0);
150 PRINT #l, CHR$(29); “C1“; CHR$( 1); CHR$(0); CHR$( 10); CHR$(0);
CHR$( 1); CHR$(1);
160 PRINT #l, CHR$(29); “C2”; CHR$( 1); CHR$(0);
170 FOR I = 1 TO 10
180 PRINT #1, CHR$(29); ”c”;
190 PRINT #l, CHR$(12);
200
NEXT I
210 PRINT #l, “ABCDEF”; CHR$( 10);
220
PRINT #l, CHR$(29); CHR$(12);
230 CLOSE #1