5 Serial Connection
When the TM printer is connected to the host PC with a serial interface, the usable serial cross
cable is as follows:
6 Self-test Mode
In self-test mode, the following items are checked and printed out:
•Control software version
DIP switch settings
And others.
Use the following procedure to start a self-test.
1. To start the selftest, hold down the FEED button (*1)(*2) and turn on the printer with the roll
paper cover closed.
Note:
(*1) With the TM-J2000/TM-J2100, hold down the PAPER FEED button instead of the FEED button.
(*2) With the TM-L90, keep holding down the FEED button until the ERROR LED comes on.
2. After printing the current printer status, the printer prints the message to show the standby
state; then the paper out LED blinks. The printer is now in the self-test wait mode.
3. To start a test print, press the FEED button when the printer is in the self-test wait mode.
4. Make sure that the following message is printed.
*** completed ***